PLC Engine Collect connects programable controllers,
supervisory control systemd and devices among themselves and with the
automation world. It connects controllers and databases, too. Likewise
it works as OPC server and OPC client to SCADA Systems.
Take Your tablet or smartphone for a fast view oy Your plant.
Over Ethernet it offers access to the controllers from the companies
Siemens, Rockwell Automation, Mitsubishi, Wago, Modicon, Schneider Electric and
others.
OPC UA openes for the Industrie 4.0 world.
PLC Engine Collect is simply to configure. Wizards are offering frequently needed
predefined functions.
PLC Engine Collect is the perfect component for using it for communications in Industrie 4.0.
The PLC Engine allows data processing in production lines.
It connects controllers, devices, SCADA systems and databases from various
manufacturers. It processes the data and dispatches them between the
connected devices and other systems. It collects data, manages them and
creates overviews for OEE applications.
Additional all the data can be handled over OPC. This are processed data and
all data from the connected controllers, devices, OPC systems and databases.
PLC Engine is the perfect component for using it for communications in
Industrie 4.0.
Functionality
With logic tables you define all the things your plant will need:- Read and write data from industrial controllers and devices.
- Exchange data with databases. Read, write, update, delete.
- Read and write files, check for changes, create files, delete files.
- Send emails.
- Read and write data over OPC UA and Classic OP.
- Sequence chains with conditions for changing the actual step.
- Calculate data. Round, basic calculations, constants, conversions, reinterpretations.
- Check data. AND OR XOR NOT. Comparisons for equal, less, greater. Float number plausability.
- Manage data structures. Create them, decode structures.
- Collect data. Combine and separate texts. Combine and separate binary data.
- Lots of triggers: Time trigger, data change trigger, bit trigger, file create trigger, file modify trigger, directory change trigger.
- Subroutines.
- Handle UPC UA function calls (RPC).
- Generate OPC UA events.
Online diagnostics for shortening the configuration time
- Watch connections and their state.
- Watch variables. Status, value, who needs them.
- Watch logic tables and their behaviour.
- Watch and modify single variables (Status variable).
- Diagnostics logger for long term watching.
Configuration
The configuration works in graphical style or with simple lists.
Lot of Wizards simplify this.
The example logs from barcode reader, adds a timestamp and writes both into a .csv file.
This example reads a barcode, gets the print data from a database and prints the result.
Diagnostics boost the startup in plants. Use Your smartphone or tablet and all of the status displays.
The diagnostics logger handles longer running information collecting.
Le PLC Engine Collect est particulièrement adapté à une utilisation dans les systèmes dans lesquels des commandes et des dispositifs de différents fabricants sont utilisés.
Pris en charge Contrôles et les dispositifs |
|
Soutenu Interfaces OPC |
|
Soutenu Interface MQTT |
|
Soutenu Bases de données |
|
Supporté systèmes d'exploitation |
|
Basis | Siemens | Rockwell | Mitsubishi | IEC60870 | BACnet | De Luxe | Multix | Maximum | ||
Les protocoles de transport | TCP/IP | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ |
OSI/H1 | ✔ | |||||||||
Les protocoles d'application | Siemens S7 1500/1200 300/400 | ✔ | ✔ | ✔ | ✔ | |||||
Siemens S5 | ✔ | ✔ | ✔ | |||||||
ControlLogix CompactLogix SLC PLC5 Micro8xx | ✔ | ✔ | ✔ | ✔ | ||||||
Mitsubishi | ✔ | ✔ | ✔ | ✔ | ||||||
BACnet | ✔ | ✔ | ✔ | ✔ | ||||||
KNX | ✔ | ✔ | ✔ | ✔ | ||||||
IEC 60870-5 | ✔ | ✔ | ✔ | ✔ | ||||||
Modbus | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | |
MQTT | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | |
OPC UA | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | |
Send / Receive | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | ✔ | |
Windows OPC DA classic | ✔ | ✔ |
PLC Engine Collect Multix, Connexions à la base de données 100, 50 000 Éléments, Tableaux logiques en 200 | |
Database Large, Tableaux logiques en 500 PLC Engine Collect Multix Database Large for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 100 PLC Client Connections • 50 000 Éléments • Tableaux logiques en 500 • Connexions à la base de données 20 • 1 000 Elements per Logic Table • 100 OPC UA Client Connections • 100 OPC Pipe Client Connections • 200 OPC UA Server Connections • 100 OPC Pipe Server Connections • 100 MQTT Connections • 100 KNX Client Connections • 100 PLC Server Connections Fonctions sous licence: • Connexions TCP/IP • Connexions série • Connexions Siemens S5 • Connexions Siemens S7-200/300/400 • Connexions Siemens S7-1200/1500 • Connexions Rockwell CompactLogic/ControlLogix • Connexions Mitsubishi Melsec Q • Modbus TCP/RTU Client Connections • Modbus TCP/RTU Server Connections • Connexions de données brutes • Connexions d'envoi de courrier électronique • Connexion BacNet • KNX Connections • IEC60870-5-104 / DNP3 Connections • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connexions • MySql Connexions • MsSql Connections • ODBC Connections • PostgreSQL Connections • Fonctionnalité du serveur de données PLC • Fonctionnalité d'accès au PLC • Fonctionnalité des tableaux logiques minimaux • Fonctionnalités des tableaux logiques complets • Permet l'utilisation de licences Supplément • Connexion dynamique et création de variables • Item Redirect Connection | 104-0031-06 V2 |
Base de données PLC Engine Collect Multix Database for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 100 PLC Client Connections • 50 000 Éléments • Tableaux logiques en 200 • Connexions à la base de données 20 • 1 000 Elements per Logic Table • 100 OPC UA Client Connections • 100 OPC Pipe Client Connections • 200 OPC UA Server Connections • 100 OPC Pipe Server Connections • 100 MQTT Connections • 100 KNX Client Connections • 100 PLC Server Connections Fonctions sous licence: • Connexions TCP/IP • Connexions série • Connexions Siemens S5 • Connexions Siemens S7-200/300/400 • Connexions Siemens S7-1200/1500 • Connexions Rockwell CompactLogic/ControlLogix • Connexions Mitsubishi Melsec Q • Modbus TCP/RTU Client Connections • Modbus TCP/RTU Server Connections • Connexions de données brutes • Connexions d'envoi de courrier électronique • Connexion BacNet • KNX Connections • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connexions • MySql Connexions • MsSql Connections • ODBC Connections • PostgreSQL Connections • Fonctionnalité du serveur de données PLC • Fonctionnalité d'accès au PLC • Fonctionnalité des tableaux logiques minimaux • Fonctionnalités des tableaux logiques complets • Permet l'utilisation de licences Supplément • Connexion dynamique et création de variables • Item Redirect Connection | 104-0031-05 V2 |
Multix Normal PLC Engine Collect Multix for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 100 PLC Client Connections • 50 000 Éléments • Tableaux logiques en 200 • 1 000 Elements per Logic Table • 100 OPC UA Client Connections • 100 OPC Pipe Client Connections • 200 OPC UA Server Connections • 100 OPC Pipe Server Connections • 100 MQTT Connections • 100 KNX Client Connections • 100 PLC Server Connections Fonctions sous licence: • Connexions TCP/IP • Connexions série • Connexions Siemens S5 • Connexions Siemens S7-200/300/400 • Connexions Siemens S7-1200/1500 • Connexions Rockwell CompactLogic/ControlLogix • Connexions Mitsubishi Melsec Q • Modbus TCP/RTU Client Connections • Modbus TCP/RTU Server Connections • Connexions de données brutes • Connexions d'envoi de courrier électronique • Connexion BacNet • KNX Connections • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connexions • Fonctionnalité du serveur de données PLC • Fonctionnalité d'accès au PLC • Fonctionnalité des tableaux logiques minimaux • Fonctionnalités des tableaux logiques complets • Permet l'utilisation de licences Supplément • Connexion dynamique et création de variables • Item Redirect Connection | 104-0031-04 V2 |
PLC Engine Collect Standard, Connexions à la base de données 50, 10 000 Éléments, Tableaux logiques en 100 | |
Siemens S7 1500 PLC Engine Collect Standard Siemens S7 1500 for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 50 PLC Client Connections • 10 000 Éléments • Tableaux logiques en 100 • 1 000 Elements per Logic Table • 50 OPC UA Client Connections • 50 OPC Pipe Client Connections • 100 OPC UA Server Connections • 100 OPC Pipe Server Connections • 50 MQTT Connections Fonctions sous licence: • Connexions TCP/IP • Connexions série • Connexions Siemens S7-1200/1500 • Modbus TCP/RTU Client Connections • Connexions de données brutes • Connexions d'envoi de courrier électronique • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connexions • Fonctionnalité du serveur de données PLC • Fonctionnalité d'accès au PLC • Fonctionnalité des tableaux logiques minimaux • Fonctionnalités des tableaux logiques complets • Permet l'utilisation de licences Supplément • Connexion dynamique et création de variables • Item Redirect Connection | 104-0011-02 V2 |
Bases PLC Engine Collect Standard Basis for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 50 PLC Client Connections • 10 000 Éléments • Tableaux logiques en 100 • 1 000 Elements per Logic Table • 50 OPC UA Client Connections • 50 OPC Pipe Client Connections • 100 OPC UA Server Connections • 100 OPC Pipe Server Connections • 50 MQTT Connections Fonctions sous licence: • Connexions TCP/IP • Connexions série • Modbus TCP/RTU Client Connections • Connexions de données brutes • Connexions d'envoi de courrier électronique • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connexions • Fonctionnalité du serveur de données PLC • Fonctionnalité d'accès au PLC • Fonctionnalité des tableaux logiques minimaux • Fonctionnalités des tableaux logiques complets • Permet l'utilisation de licences Supplément • Connexion dynamique et création de variables • Item Redirect Connection | 104-0001-01 V2 |
PLC Engine Collect Small, Connexions à la base de données 5, 3 000 Éléments, Tableaux logiques en 25 | |
Interconnection PLC Engine Collect Small Interconnection for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 5 PLC Client Connections • 3 000 Éléments • Tableaux logiques en 25 • 1 000 Elements per Logic Table • 5 OPC UA Client Connections • 5 OPC Pipe Client Connections • 20 OPC UA Server Connections • 20 OPC Pipe Server Connections • 5 MQTT Connections Fonctions sous licence: • Connexions TCP/IP • Connexions OSI/H1 • Connexions série • Connexions Siemens S5 • Connexions Siemens S7-200/300/400 • Connexions Siemens S7-1200/1500 • Connexions Rockwell CompactLogic/ControlLogix • Connexions Mitsubishi Melsec Q • Modbus TCP/RTU Client Connections • Connexions de données brutes • Connexions d'envoi de courrier électronique • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connexions • Fonctionnalité du serveur de données PLC • Fonctionnalité d'accès au PLC • Fonctionnalité des tableaux logiques minimaux • Fonctionnalités des tableaux logiques complets • Connexion dynamique et création de variables • Item Redirect Connection • Doesn't allow the use of Addon licenses | 104-0431-01 V2 |
PLC Engine Collect Small Base de Données, Connexions à la base de données 5, 3 000 Éléments, Tableaux logiques en 25 | |
Siemens S7 PLC Engine Collect Small Database Siemens S7 for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 5 PLC Client Connections • 3 000 Éléments • Tableaux logiques en 25 • Connexions à la base de données 20 • 1 000 Elements per Logic Table • 5 OPC UA Client Connections • 5 OPC Pipe Client Connections • 20 OPC UA Server Connections • 20 OPC Pipe Server Connections • 5 MQTT Connections Fonctions sous licence: • Connexions TCP/IP • Connexions série • Connexions Siemens S7-200/300/400 • Connexions Siemens S7-1200/1500 • Modbus TCP/RTU Client Connections • Connexions de données brutes • Connexions d'envoi de courrier électronique • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connexions • MySql Connexions • MsSql Connections • ODBC Connections • PostgreSQL Connections • Fonctionnalité du serveur de données PLC • Fonctionnalité d'accès au PLC • Fonctionnalité des tableaux logiques minimaux • Fonctionnalités des tableaux logiques complets • Connexion dynamique et création de variables • Item Redirect Connection • Doesn't allow the use of Addon licenses | 104-0311-01 V2 |
Rockwell PLC Engine Collect Small Database Rockwell for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 5 PLC Client Connections • 3 000 Éléments • Tableaux logiques en 25 • Connexions à la base de données 20 • 1 000 Elements per Logic Table • 5 OPC UA Client Connections • 5 OPC Pipe Client Connections • 20 OPC UA Server Connections • 20 OPC Pipe Server Connections • 5 MQTT Connections Fonctions sous licence: • Connexions TCP/IP • Connexions série • Connexions Rockwell CompactLogic/ControlLogix • Modbus TCP/RTU Client Connections • Connexions de données brutes • Connexions d'envoi de courrier électronique • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connexions • MySql Connexions • MsSql Connections • ODBC Connections • PostgreSQL Connections • Fonctionnalité du serveur de données PLC • Fonctionnalité d'accès au PLC • Fonctionnalité des tableaux logiques minimaux • Fonctionnalités des tableaux logiques complets • Connexion dynamique et création de variables • Item Redirect Connection • Doesn't allow the use of Addon licenses | 104-0321-01 V2 |
Bases, Connexions à la base de données 20 PLC Engine Collect Small Database Basis for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 20 PLC Client Connections • 3 000 Éléments • Tableaux logiques en 25 • Connexions à la base de données 20 • 1 000 Elements per Logic Table • 5 OPC UA Client Connections • 5 OPC Pipe Client Connections • 20 OPC UA Server Connections • 20 OPC Pipe Server Connections • 5 MQTT Connections Fonctions sous licence: • Connexions TCP/IP • Connexions série • Modbus TCP/RTU Client Connections • Connexions de données brutes • Connexions d'envoi de courrier électronique • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connexions • MySql Connexions • MsSql Connections • ODBC Connections • PostgreSQL Connections • Fonctionnalité du serveur de données PLC • Fonctionnalité d'accès au PLC • Fonctionnalité des tableaux logiques minimaux • Fonctionnalités des tableaux logiques complets • Connexion dynamique et création de variables • Item Redirect Connection • Doesn't allow the use of Addon licenses | 104-0301-01 V2 |
PLC Engine Collect Minimum, Connexions à la base de données 2, 1 000 Éléments, Tableaux logiques en 10 | |
Multix PLC Engine Collect Minimum Multix for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 2 PLC Client Connections • 1 000 Éléments • Tableaux logiques en 10 • 1 000 Elements per Logic Table • 2 OPC UA Client Connections • 2 OPC Pipe Client Connections • 10 OPC UA Server Connections • 10 OPC Pipe Server Connections • 2 MQTT Connections Fonctions sous licence: • Connexions TCP/IP • Connexions série • Connexions Siemens S7-200/300/400 • Connexions Siemens S7-1200/1500 • Connexions Rockwell CompactLogic/ControlLogix • Connexions Mitsubishi Melsec Q • Modbus TCP/RTU Client Connections • Connexions de données brutes • Connexions d'envoi de courrier électronique • Connexion BacNet • KNX Connections • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connexions • Fonctionnalité du serveur de données PLC • Fonctionnalité d'accès au PLC • Fonctionnalité des tableaux logiques minimaux • Fonctionnalités des tableaux logiques complets • Connexion dynamique et création de variables • Item Redirect Connection • Doesn't allow the use of Addon licenses | 104-0131-02 V2 |
Siemens S7 1500 PLC Engine Collect Minimum Siemens S7 1500 for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 2 PLC Client Connections • 1 000 Éléments • Tableaux logiques en 10 • 1 000 Elements per Logic Table • 2 OPC UA Client Connections • 2 OPC Pipe Client Connections • 10 OPC UA Server Connections • 10 OPC Pipe Server Connections • 2 MQTT Connections Fonctions sous licence: • Connexions TCP/IP • Connexions série • Connexions Siemens S7-1200/1500 • Modbus TCP/RTU Client Connections • Connexions de données brutes • Connexions d'envoi de courrier électronique • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connexions • Fonctionnalité du serveur de données PLC • Fonctionnalité d'accès au PLC • Fonctionnalité des tableaux logiques minimaux • Fonctionnalités des tableaux logiques complets • Connexion dynamique et création de variables • Item Redirect Connection • Doesn't allow the use of Addon licenses | 104-0111-02 V2 |
Rockwell PLC Engine Collect Minimum Rockwell for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 2 PLC Client Connections • 1 000 Éléments • Tableaux logiques en 10 • 1 000 Elements per Logic Table • 2 OPC UA Client Connections • 2 OPC Pipe Client Connections • 10 OPC UA Server Connections • 10 OPC Pipe Server Connections • 2 MQTT Connections Fonctions sous licence: • Connexions TCP/IP • Connexions série • Connexions Rockwell CompactLogic/ControlLogix • Modbus TCP/RTU Client Connections • Connexions de données brutes • Connexions d'envoi de courrier électronique • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connexions • Fonctionnalité du serveur de données PLC • Fonctionnalité d'accès au PLC • Fonctionnalité des tableaux logiques minimaux • Fonctionnalités des tableaux logiques complets • Connexion dynamique et création de variables • Item Redirect Connection • Doesn't allow the use of Addon licenses | 104-0121-01 V2 |
Bases PLC Engine Collect Minimum Basis for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 2 PLC Client Connections • 1 000 Éléments • Tableaux logiques en 10 • 1 000 Elements per Logic Table • 2 OPC UA Client Connections • 2 OPC Pipe Client Connections • 10 OPC UA Server Connections • 10 OPC Pipe Server Connections • 2 MQTT Connections Fonctions sous licence: • Connexions TCP/IP • Connexions série • Modbus TCP/RTU Client Connections • Connexions de données brutes • Connexions d'envoi de courrier électronique • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connexions • Fonctionnalité du serveur de données PLC • Fonctionnalité d'accès au PLC • Fonctionnalité des tableaux logiques minimaux • Fonctionnalités des tableaux logiques complets • Connexion dynamique et création de variables • Item Redirect Connection • Doesn't allow the use of Addon licenses | 104-0101-01 V2 |
PLC Engine Collect Minimum Base de Données, Connexions à la base de données 2, 1 000 Éléments, Tableaux logiques en 10 | |
Siemens S7 PLC Engine Collect Minimum Database Siemens S7 for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 2 PLC Client Connections • 1 000 Éléments • Tableaux logiques en 10 • Connexions à la base de données 20 • 1 000 Elements per Logic Table • 2 OPC UA Client Connections • 2 OPC Pipe Client Connections • 10 OPC UA Server Connections • 10 OPC Pipe Server Connections • 2 MQTT Connections Fonctions sous licence: • Connexions TCP/IP • Connexions série • Connexions Siemens S7-200/300/400 • Connexions Siemens S7-1200/1500 • Modbus TCP/RTU Client Connections • Connexions de données brutes • Connexions d'envoi de courrier électronique • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connexions • MySql Connexions • MsSql Connections • ODBC Connections • PostgreSQL Connections • Fonctionnalité du serveur de données PLC • Fonctionnalité d'accès au PLC • Fonctionnalité des tableaux logiques minimaux • Fonctionnalités des tableaux logiques complets • Connexion dynamique et création de variables • Item Redirect Connection • Doesn't allow the use of Addon licenses | 104-0211-01 V2 |
Rockwell PLC Engine Collect Minimum Database Rockwell for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 2 PLC Client Connections • 1 000 Éléments • Tableaux logiques en 10 • Connexions à la base de données 20 • 1 000 Elements per Logic Table • 2 OPC UA Client Connections • 2 OPC Pipe Client Connections • 10 OPC UA Server Connections • 10 OPC Pipe Server Connections • 2 MQTT Connections Fonctions sous licence: • Connexions TCP/IP • Connexions série • Connexions Rockwell CompactLogic/ControlLogix • Modbus TCP/RTU Client Connections • Connexions de données brutes • Connexions d'envoi de courrier électronique • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connexions • MySql Connexions • MsSql Connections • ODBC Connections • PostgreSQL Connections • Fonctionnalité du serveur de données PLC • Fonctionnalité d'accès au PLC • Fonctionnalité des tableaux logiques minimaux • Fonctionnalités des tableaux logiques complets • Connexion dynamique et création de variables • Item Redirect Connection • Doesn't allow the use of Addon licenses | 104-0221-01 V2 |
Bases PLC Engine Collect Minimum Database Basis for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 2 PLC Client Connections • 1 000 Éléments • Tableaux logiques en 10 • Connexions à la base de données 20 • 1 000 Elements per Logic Table • 2 OPC UA Client Connections • 2 OPC Pipe Client Connections • 10 OPC UA Server Connections • 10 OPC Pipe Server Connections • 2 MQTT Connections Fonctions sous licence: • Connexions TCP/IP • Connexions série • Modbus TCP/RTU Client Connections • Connexions de données brutes • Connexions d'envoi de courrier électronique • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connexions • MySql Connexions • MsSql Connections • ODBC Connections • PostgreSQL Connections • Fonctionnalité du serveur de données PLC • Fonctionnalité d'accès au PLC • Fonctionnalité des tableaux logiques minimaux • Fonctionnalités des tableaux logiques complets • Connexion dynamique et création de variables • Item Redirect Connection • Doesn't allow the use of Addon licenses | 104-0201-01 V2 |
PLC Engine Collect: Recueillir des données et le serveur OPC, Connexion client 1, 10 Éléments, Tableaux logiques en 5 | |
Siemens S7 PLC Engine Collect Nano Siemens S7 for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 1 PLC Client Connection • 10 Éléments • Tableaux logiques en 5 • 1 000 Elements per Logic Table • 1 OPC UA Client Connection • 1 OPC Pipe Client Connection • 5 OPC UA Server Connections • 5 OPC Pipe Server Connections • 1 MQTT Connection Fonctions sous licence: • Connexions TCP/IP • Connexions série • Connexions Siemens S7-200/300/400 • Connexions Siemens S7-1200/1500 • Modbus TCP/RTU Client Connections • Connexions de données brutes • Connexions d'envoi de courrier électronique • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connexions • Fonctionnalité du serveur de données PLC • Fonctionnalité d'accès au PLC • Fonctionnalité des tableaux logiques minimaux • Fonctionnalités des tableaux logiques complets • Connexion dynamique et création de variables • Item Redirect Connection • Doesn't allow the use of Addon licenses | 104-0511-01 V2 |
Bases PLC Engine Collect Nano Basis for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 1 PLC Client Connection • 10 Éléments • Tableaux logiques en 5 • 1 000 Elements per Logic Table • 1 OPC UA Client Connection • 1 OPC Pipe Client Connection • 5 OPC UA Server Connections • 5 OPC Pipe Server Connections • 1 MQTT Connection Fonctions sous licence: • Connexions TCP/IP • Connexions série • Modbus TCP/RTU Client Connections • Connexions de données brutes • Connexions d'envoi de courrier électronique • OpcPipe Server Connections • OPC UA Server Connections • OpcPipe Client Connections • OPC UA Client Connections • MQTT Connexions • Fonctionnalité du serveur de données PLC • Fonctionnalité d'accès au PLC • Fonctionnalité des tableaux logiques minimaux • Fonctionnalités des tableaux logiques complets • Connexion dynamique et création de variables • Item Redirect Connection • Doesn't allow the use of Addon licenses | 104-0501-01 V2 |
Supplément | |
Licenciement Supplément Redondance for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others Fonctions sous licence: • Connexions redondantes | 100-0001-01 V2 |
1 000 Raccordements Addon 1 000 Connexions for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 1 000 PLC Client Connections • 1 000 OPC UA Client Connections • 1 000 OPC UA Server Connections • 1 000 IEC104 Client Connections • 1 000 PLC Server Connections | 100-0001-02 V2 |
100 000 Éléments Addon 100 000 Éléments for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 100 000 Éléments | 101-0001-06 V2 |
200 Raccordements 1 000 000 Éléments Complément 200 Raccordements 1 000 000 Eléments for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 200 PLC Client Connections • 1 000 000 Éléments • 200 OPC UA Client Connections • 200 OPC UA Server Connections • 200 MQTT Connections • 200 IEC104 Client Connections • 200 PLC Server Connections | 101-0001-02 V2 |
2 500 Connections 4 000 000 Items Complément 2500 Raccordements 4 000 000 Eléments for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 2 500 PLC Client Connections • 4 000 000 Éléments • 2 500 OPC UA Client Connections • 2 500 OPC UA Server Connections • 2 500 MQTT Connections • 2 500 IEC104 Client Connections • 2 500 PLC Server Connections | 101-0001-08 V2 |
OPC DA Client and Server Addon OPC DA Client and Server for Windows 7 and newer on PC • 200 OPC DA Client Connections • 200 OPC DA Server Connections Fonctions sous licence: • Fonctionnalité du serveur OPC DA • OPC DA Client Connections | 100-0001-03 V2 |
BACnet KNX Addon BACnet KNX for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 50 PLC Client Connections • 50 KNX Client Connections Fonctions sous licence: • Modbus TCP/RTU Client Connections • Connexions de données brutes • Connexion BacNet • KNX Connections • Fonctionnalité d'accès au PLC | 100-0001-04 V2 |
Connexions série Addon Connexions série for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others Fonctions sous licence: • Connexions série | 100-0001-05 V2 |
DA Server Functions Addon DA Server Functions for Windows 7 and newer on PC • 200 OPC DA Server Connections Fonctions sous licence: • Fonctionnalité du serveur OPC DA | 101-0000-01 V2 |
Siemens S7 1500 Addon Siemens S7 1500 for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 50 PLC Client Connections Fonctions sous licence: • Connexions Siemens S7-1200/1500 • Modbus TCP/RTU Client Connections • Connexions de données brutes • Fonctionnalité d'accès au PLC | 100-0001-08 V2 |
Siemens S7 200/300/400 Addon Siemens S7 200/300/400 for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 50 PLC Client Connections Fonctions sous licence: • Connexions Siemens S7-200/300/400 • Modbus TCP/RTU Client Connections • Connexions de données brutes • Fonctionnalité d'accès au PLC | 100-0001-09 V2 |
Siemens S5 Addon Siemens S5 for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 50 PLC Client Connections Fonctions sous licence: • Connexions Siemens S5 • Modbus TCP/RTU Client Connections • Connexions de données brutes • Fonctionnalité d'accès au PLC | 101-0011-03 V2 |
Rockwell Addon Rockwell for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 50 PLC Client Connections Fonctions sous licence: • Connexions Rockwell CompactLogic/ControlLogix • Modbus TCP/RTU Client Connections • Connexions de données brutes • Fonctionnalité d'accès au PLC | 101-0021-02 V2 |
Mitsubishi Addon Mitsubishi for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 50 PLC Client Connections Fonctions sous licence: • Connexions Mitsubishi Melsec Q • Modbus TCP/RTU Client Connections • Connexions de données brutes • Fonctionnalité d'accès au PLC | 101-0051-02 V2 |
IEC60870-5-104 Addon IEC60870-5-104 for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • 50 PLC Client Connections • 100 IEC104 Client Connections Fonctions sous licence: • Modbus TCP/RTU Client Connections • Connexions de données brutes • IEC60870-5-104 / DNP3 Connections • Fonctionnalité d'accès au PLC | 100-0001-06 V2 |
Complément PLC Engine Collect | |
10 000 Tableaux Logiques Addon PLC Engine Collect 10 000 Logic Tables for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • Tableaux logiques en 10 000 | 104-0001-05 V2 |
4 onnexions à la base de données Addon PLC Engine Collect Database Access for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others • Connexions à la base de données 20 Fonctions sous licence: • MySql Connexions • MsSql Connections • ODBC Connections • PostgreSQL Connections | 104-0001-02 V2 |
Extended OPC Services for Machine Models Addon PLC Engine Collect Extended OPC Services for Machine Models for Windows 7 and newer on PC, Linux for PC, Raspberry, Odroid and others Fonctions sous licence: • OPC UA Internal Variable Access • OPC UA Remote Procedure Calls • OPC UA Events | 104-0001-08 V2 |
Tools | |
OPC UA Modeler OPC UA Modeler | 107-0001-01 V2 |
Protection des logiciels par dongle
Without a license all PLC Engine Collect will work for three days after each start.